Skip to content

SeamData

Defines the start and end phase data of a welding seam. Allows detailed specification of timing and arc conditions across three phases: Ignition, Heat, and End. Typically, the same values are maintained for an entire seam or across multiple seams.

Name Type Description
Weld Sched Weld Sched The welding program number (schedule) and welding mode to be utilized.
Weight Number Weight factor applied to wirefeed1.
Name Type Description
Name String Variable name.
Link ArcData Boolean Links ArcData values across all sequences (Ignition, Heat, End). TRUE: Adjusting parameters in one phase automatically syncs the others. FALSE: Allows independent tracking for each phase (Default).
Name Type Description
Voltage Number Welding voltage (ABB convention). For Fronius TPS/TPS-i: Adjusts the arc length.
Wirefeed(m/min) Number Wire feed speed (m/min). Common to both ABB and Fronius systems.
Control Number Control parameter (ABB convention). For Fronius TPS/TPS-i: Adjusts dynamic characteristics.
Current Number Welding current (ABB convention). Not utilized in Fronius TPS/TPS-i setups.

Name Type Description
Purge Time Number Gas pre-purge duration (s) required to fill the gas line and weld torch. If travel time to the start position is shorter than the purge time, the robot dwells at the start position until the timer expires.
Purgeflow Time Number Shielding gas pre-flow duration (s) over the weldment. The robot remains stationary at the ignition location during this window before the arc is initiated.
Move Delay Number Dwell time delay (s) from the point of arc stabilization at ignition until the primary heating phase begins.

Name Type Description
SeamData SeamData Outputs the configured ABB SeamData configuration stream.
Code String Outputs the compiled RAPID instruction code.